Neon (Ne)

Lennard-Jones parameters

Some Lennard-Jones parameters for neon are listed in the following table:

Authors ϵ (meV) σ (nm) Reference
Herrero 3.0840 0.2782 [1]
Ramírez and Herrero 3.2135 0.2782 [2]

Buckingham potential

The Buckingham potential for neon is given by (Eq. 26 [3]):

E(r)=25.7×10−10e−r/0.235−9×10−12r−6

where E is in ergs ( 10−7 J) and r in Å.

Phase diagram

The phase diagram for temperatures in the range of 17–50 K and pressures between 10−2 and 2×103 bar has been calculated in Ref. 2. The critical point was located at Tc=46.7K and pc=27.7 bar (Ref. 2 Table I), and the triple point at Ttp=24.55K and ptp=0.315 bar (Ref. 2 Table II).

References