The Berendsen barostat [1] is a method for controlling the pressure in a molecular dynamics simulation. The Berendsen barostat adds an extra term to to the equations of motion which effects the pressure change (Eq. 12):

dPdt|bath=P0−PτP

where P0 is the reference pressure, i.e. the pressure of the external pressure "bath", and P is the instantaneous pressure. τP is a time constant. Within this scheme the coordinates and the box sides are rescaled every step. Assuming the system is isotropic and within a cubic box the scaling factor μ is given by (Eq. 20):

μ=1−κTΔt3τP(P0−P)

where κT is the isothermal compressibility. The value of κT only has to be reasonable; for example, both DL POLY and GROMACS use the value of the compressibility of water (at 1 atm and 300K, leading to κT=4.6×10−5bar−1).